{"id":2272,"date":"2023-11-20T14:42:34","date_gmt":"2023-11-20T19:42:34","guid":{"rendered":"https:\/\/www.med.unc.edu\/hic-imaging\/?page_id=2272"},"modified":"2024-06-05T11:45:22","modified_gmt":"2024-06-05T15:45:22","slug":"olympus-fluoview-1000-confocal","status":"publish","type":"page","link":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/","title":{"rendered":"Olympus Fluoview 1000 Confocal"},"content":{"rendered":"<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-2317 size-medium\" src=\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638-300x300.jpg\" alt=\"Olympus Fluoview 1000 Confocal Microscope\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638-300x300.jpg 300w, https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638-150x150.jpg 150w, https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638.jpg 480w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/h3>\n<p>A confocal laser scanning microscope mounted on an inverted IX-81 stand.<!-- notionvc: e7cfe0cd-f5c4-48c3-b2a0-023df5d69626 --><\/p>\n<h2>Features<\/h2>\n<ul>\n<li>A synchronized SIM Scanner allowing for coordination of laser stimulation and imaging, an ideal choice for FRAP, FLIP and photoactivation<\/li>\n<li>Environmental chamber for maintaining living cells<\/li>\n<li>Tiling and imaging multiple locations<\/li>\n<li>CFP\/YFP FRET<\/li>\n<\/ul>\n<p><!-- notionvc: 91086397-aa86-424a-a7c1-d50a8117ee08 --><\/p>\n<hr \/>\n<h2>Location: 238 Taylor Hall<\/h2>\n<hr \/>\n<h2>Specifications<\/h2>\n<h3>Objectives<\/h3>\n<ul>\n<li>UPlanSApo 4x\/0.16 WD 13mm<\/li>\n<li>UPlanSApo 10x\/0.4 WD3.1mm<\/li>\n<li>UPlanSApo 20x\/0.75 WD 0.55mm<\/li>\n<li>UPlanSApo 30x\/1.05 Silicon WD 0.880mm<\/li>\n<li>PlanApo 60x\/1.42 oil WD 0.150mm<\/li>\n<li>LUMPlanF IN 60x\/1.00 water WD 2mm<!-- notionvc: 24993ce6-e303-4c0c-b56f-817c462ec5fa --><!-- notionvc: ab71a635-3198-46fa-9401-58d684b38b51 --><\/li>\n<\/ul>\n<h3>Excitation Lines<\/h3>\n<ul>\n<li>405nm: 50mW<\/li>\n<li>559nm: 15mW<\/li>\n<li>635nm:20mW<\/li>\n<li>Multiline Argon laser (440nm, 488nm, 515nm, Total 30mW)<!-- notionvc: 70e3f257-485b-4405-a649-91f2b2a43d7c --><!-- notionvc: abed3f19-645c-424d-9e12-4654f5c53726 --><\/li>\n<\/ul>\n<h3>Epifluorescence Filters<\/h3>\n<ul>\n<li>DAPI<\/li>\n<li>FITC\/GFP<\/li>\n<li>Texas Red\/Rhodamine<!-- notionvc: 44145e34-afb3-45c2-842e-738065aa854d --><!-- notionvc: 3b4a3755-b976-4e14-a7a5-b1a5d8187c96 --><\/li>\n<\/ul>\n<h3>Detection<\/h3>\n<ul>\n<li>4 Confocal Channels &amp; TD (transmitted light detector), Ch1 &amp; Ch 2 are spectral, Ch3 &amp; Ch 4 use barrier filters<!-- notionvc: 090c2394-97a3-45a1-8cc4-d13bedd01603 --><!-- notionvc: 8c5de6b9-0c78-4b1f-bcd7-7c0bae2a64a4 --><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A confocal laser scanning microscope mounted on an inverted IX-81 stand. Features A synchronized SIM Scanner allowing for coordination of laser stimulation and imaging, an ideal choice for FRAP, FLIP and photoactivation Environmental chamber for maintaining living cells Tiling and imaging multiple locations CFP\/YFP FRET Location: 238 Taylor Hall Specifications Objectives UPlanSApo 4x\/0.16 WD 13mm &hellip; <a href=\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/\" aria-label=\"Read more about Olympus Fluoview 1000 Confocal\">Read more<\/a><\/p>\n","protected":false},"author":111865,"featured_media":0,"parent":2571,"menu_order":4,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"layout":"","cellInformation":"","apiCallInformation":"","footnotes":"","_links_to":"","_links_to_target":""},"class_list":["post-2272","page","type-page","status-publish","hentry","odd"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Olympus Fluoview 1000 Confocal - Hooker Imaging Core<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Olympus Fluoview 1000 Confocal - Hooker Imaging Core\" \/>\n<meta property=\"og:description\" content=\"A confocal laser scanning microscope mounted on an inverted IX-81 stand. Features A synchronized SIM Scanner allowing for coordination of laser stimulation and imaging, an ideal choice for FRAP, FLIP and photoactivation Environmental chamber for maintaining living cells Tiling and imaging multiple locations CFP\/YFP FRET Location: 238 Taylor Hall Specifications Objectives UPlanSApo 4x\/0.16 WD 13mm &hellip; Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/\" \/>\n<meta property=\"og:site_name\" content=\"Hooker Imaging Core\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T15:45:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638-300x300.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/\",\"url\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/\",\"name\":\"Olympus Fluoview 1000 Confocal - Hooker Imaging Core\",\"isPartOf\":{\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638-300x300.jpg\",\"datePublished\":\"2023-11-20T19:42:34+00:00\",\"dateModified\":\"2024-06-05T15:45:22+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#primaryimage\",\"url\":\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638.jpg\",\"contentUrl\":\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638.jpg\",\"width\":480,\"height\":480,\"caption\":\"Olympus Fluoview 1000 Confocal Microscope\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.med.unc.edu\/hic-imaging\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instrumentation\",\"item\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Olympus Fluoview 1000 Confocal\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/#website\",\"url\":\"https:\/\/www.med.unc.edu\/hic-imaging\/\",\"name\":\"Hooker Imaging Core\",\"description\":\"Cell Biology &amp; Physiology\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.med.unc.edu\/hic-imaging\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Olympus Fluoview 1000 Confocal - Hooker Imaging Core","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/","og_locale":"en_US","og_type":"article","og_title":"Olympus Fluoview 1000 Confocal - Hooker Imaging Core","og_description":"A confocal laser scanning microscope mounted on an inverted IX-81 stand. Features A synchronized SIM Scanner allowing for coordination of laser stimulation and imaging, an ideal choice for FRAP, FLIP and photoactivation Environmental chamber for maintaining living cells Tiling and imaging multiple locations CFP\/YFP FRET Location: 238 Taylor Hall Specifications Objectives UPlanSApo 4x\/0.16 WD 13mm &hellip; Read more","og_url":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/","og_site_name":"Hooker Imaging Core","article_modified_time":"2024-06-05T15:45:22+00:00","og_image":[{"url":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638-300x300.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/","url":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/","name":"Olympus Fluoview 1000 Confocal - Hooker Imaging Core","isPartOf":{"@id":"https:\/\/www.med.unc.edu\/hic-imaging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#primaryimage"},"image":{"@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#primaryimage"},"thumbnailUrl":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638-300x300.jpg","datePublished":"2023-11-20T19:42:34+00:00","dateModified":"2024-06-05T15:45:22+00:00","breadcrumb":{"@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#primaryimage","url":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638.jpg","contentUrl":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/FV1000-e1700080956638.jpg","width":480,"height":480,"caption":"Olympus Fluoview 1000 Confocal Microscope"},{"@type":"BreadcrumbList","@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/olympus-fluoview-1000-confocal\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.med.unc.edu\/hic-imaging\/"},{"@type":"ListItem","position":2,"name":"Instrumentation","item":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/"},{"@type":"ListItem","position":3,"name":"Olympus Fluoview 1000 Confocal"}]},{"@type":"WebSite","@id":"https:\/\/www.med.unc.edu\/hic-imaging\/#website","url":"https:\/\/www.med.unc.edu\/hic-imaging\/","name":"Hooker Imaging Core","description":"Cell Biology &amp; Physiology","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.med.unc.edu\/hic-imaging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links_to":[],"_links_to_target":[],"_links":{"self":[{"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/pages\/2272","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/users\/111865"}],"replies":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/comments?post=2272"}],"version-history":[{"count":0,"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/pages\/2272\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/pages\/2571"}],"wp:attachment":[{"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/media?parent=2272"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}