{"id":2284,"date":"2023-11-20T14:53:36","date_gmt":"2023-11-20T19:53:36","guid":{"rendered":"https:\/\/www.med.unc.edu\/hic-imaging\/?page_id=2284"},"modified":"2024-06-05T11:47:28","modified_gmt":"2024-06-05T15:47:28","slug":"leica-stereo-microscope","status":"publish","type":"page","link":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/","title":{"rendered":"Leica Stereo Microscope"},"content":{"rendered":"<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-2323 size-medium\" src=\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736-300x300.jpg\" alt=\"Leica Stereo Microscope\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736-300x300.jpg 300w, https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736-150x150.jpg 150w, https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736.jpg 480w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/h3>\n<p>An automated plan-apochromatic fluorescence stereo microscope<!-- notionvc: dae164fb-7333-42cb-93d4-051ece837e95 --><br \/>\n<!-- notionvc: e653fb1d-d8a0-4363-a9a6-c8b08e7cd38c --><\/p>\n<h2>Features<\/h2>\n<ul>\n<li>The filter changer, zoom, focus, UV shutter and double iris aperture are computer controlled which allows multifluorescence experiments to be repeated quickly and accurately.<\/li>\n<li>Automatic control of Multifluorescence Experiments<\/li>\n<li>Automatic filter detection<\/li>\n<li>Automatic UV shutter<\/li>\n<\/ul>\n<p><!-- notionvc: 91086397-aa86-424a-a7c1-d50a8117ee08 --><\/p>\n<hr \/>\n<h2>Location: 234 Taylor Hall<\/h2>\n<hr \/>\n<h2>Specifications<\/h2>\n<h3>Objectives<\/h3>\n<ul>\n<li><span class=\"notion-enable-hover\" data-token-index=\"0\">2x PlanApo (230) Resolution: 840 LP\/mm=0.6 \u00b5m<\/span><\/li>\n<li><span class=\"notion-enable-hover\" data-token-index=\"0\">1x PlanApo (115) Resolution: 420 LP\/mm<\/span><!-- notionvc: 21bef218-6cdd-4910-ae0d-afc3ffd7f3d1 --><!-- notionvc: be24c63e-8e6c-4967-847d-92c01e1aca18 --><!-- notionvc: ab71a635-3198-46fa-9401-58d684b38b51 --><\/li>\n<\/ul>\n<h3>Epifluorescence Filters<\/h3>\n<ul>\n<li>Motorized filter changer: DAPI, FITC, DsRed, Cy5<!-- notionvc: 8643f29e-8668-4a2e-bb63-ae563bbede15 --><!-- notionvc: 56ca7b9f-0ead-4a5c-bec4-f434af7befb5 --><!-- notionvc: 3b4a3755-b976-4e14-a7a5-b1a5d8187c96 --><\/li>\n<\/ul>\n<h3>Detection<\/h3>\n<ul>\n<li>Cameras: ORCA ER, (1344(H) x 1024(V) pixels, 6.5\u00b5m pixel size, 8.67mm x 6.6mm chip area(2\/3-inch format), 8.8 frames\/sec; QImaging MicroPublisher 5.0, (2560 x 1920) pixels, 3.4\u00b5m pixel size, 10 bit, color camera<!-- notionvc: 89e342b6-7b8f-4e10-9d6f-812ad8725f1a --><br \/>\n<!-- notionvc: dd4b7c60-2450-406d-87c8-a1ec4576c5ef --><!-- notionvc: 8c5de6b9-0c78-4b1f-bcd7-7c0bae2a64a4 --><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>An automated plan-apochromatic fluorescence stereo microscope Features The filter changer, zoom, focus, UV shutter and double iris aperture are computer controlled which allows multifluorescence experiments to be repeated quickly and accurately. Automatic control of Multifluorescence Experiments Automatic filter detection Automatic UV shutter Location: 234 Taylor Hall Specifications Objectives 2x PlanApo (230) Resolution: 840 LP\/mm=0.6 \u00b5m &hellip; <a href=\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/\" aria-label=\"Read more about Leica Stereo Microscope\">Read more<\/a><\/p>\n","protected":false},"author":111865,"featured_media":0,"parent":2571,"menu_order":11,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"layout":"","cellInformation":"","apiCallInformation":"","footnotes":"","_links_to":"","_links_to_target":""},"class_list":["post-2284","page","type-page","status-publish","hentry","odd"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Leica Stereo Microscope - Hooker Imaging Core<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Leica Stereo Microscope - Hooker Imaging Core\" \/>\n<meta property=\"og:description\" content=\"An automated plan-apochromatic fluorescence stereo microscope Features The filter changer, zoom, focus, UV shutter and double iris aperture are computer controlled which allows multifluorescence experiments to be repeated quickly and accurately. Automatic control of Multifluorescence Experiments Automatic filter detection Automatic UV shutter Location: 234 Taylor Hall Specifications Objectives 2x PlanApo (230) Resolution: 840 LP\/mm=0.6 \u00b5m &hellip; Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/\" \/>\n<meta property=\"og:site_name\" content=\"Hooker Imaging Core\" \/>\n<meta property=\"article:modified_time\" content=\"2024-06-05T15:47:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736-300x300.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/\",\"url\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/\",\"name\":\"Leica Stereo Microscope - Hooker Imaging Core\",\"isPartOf\":{\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736-300x300.jpg\",\"datePublished\":\"2023-11-20T19:53:36+00:00\",\"dateModified\":\"2024-06-05T15:47:28+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#primaryimage\",\"url\":\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736.jpg\",\"contentUrl\":\"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736.jpg\",\"width\":480,\"height\":480,\"caption\":\"Leica Stereo Microscope\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.med.unc.edu\/hic-imaging\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instrumentation\",\"item\":\"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Leica Stereo Microscope\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.med.unc.edu\/hic-imaging\/#website\",\"url\":\"https:\/\/www.med.unc.edu\/hic-imaging\/\",\"name\":\"Hooker Imaging Core\",\"description\":\"Cell Biology &amp; Physiology\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.med.unc.edu\/hic-imaging\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Leica Stereo Microscope - Hooker Imaging Core","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/","og_locale":"en_US","og_type":"article","og_title":"Leica Stereo Microscope - Hooker Imaging Core","og_description":"An automated plan-apochromatic fluorescence stereo microscope Features The filter changer, zoom, focus, UV shutter and double iris aperture are computer controlled which allows multifluorescence experiments to be repeated quickly and accurately. Automatic control of Multifluorescence Experiments Automatic filter detection Automatic UV shutter Location: 234 Taylor Hall Specifications Objectives 2x PlanApo (230) Resolution: 840 LP\/mm=0.6 \u00b5m &hellip; Read more","og_url":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/","og_site_name":"Hooker Imaging Core","article_modified_time":"2024-06-05T15:47:28+00:00","og_image":[{"url":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736-300x300.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/","url":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/","name":"Leica Stereo Microscope - Hooker Imaging Core","isPartOf":{"@id":"https:\/\/www.med.unc.edu\/hic-imaging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#primaryimage"},"image":{"@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#primaryimage"},"thumbnailUrl":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736-300x300.jpg","datePublished":"2023-11-20T19:53:36+00:00","dateModified":"2024-06-05T15:47:28+00:00","breadcrumb":{"@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#primaryimage","url":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736.jpg","contentUrl":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-content\/uploads\/sites\/1291\/2023\/11\/LeicaStereo-e1700081472736.jpg","width":480,"height":480,"caption":"Leica Stereo Microscope"},{"@type":"BreadcrumbList","@id":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/leica-stereo-microscope\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.med.unc.edu\/hic-imaging\/"},{"@type":"ListItem","position":2,"name":"Instrumentation","item":"https:\/\/www.med.unc.edu\/hic-imaging\/instrumentation\/"},{"@type":"ListItem","position":3,"name":"Leica Stereo Microscope"}]},{"@type":"WebSite","@id":"https:\/\/www.med.unc.edu\/hic-imaging\/#website","url":"https:\/\/www.med.unc.edu\/hic-imaging\/","name":"Hooker Imaging Core","description":"Cell Biology &amp; Physiology","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.med.unc.edu\/hic-imaging\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links_to":[],"_links_to_target":[],"_links":{"self":[{"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/pages\/2284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/users\/111865"}],"replies":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/comments?post=2284"}],"version-history":[{"count":0,"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/pages\/2284\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/pages\/2571"}],"wp:attachment":[{"href":"https:\/\/www.med.unc.edu\/hic-imaging\/wp-json\/wp\/v2\/media?parent=2284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}