{"id":3287,"date":"2023-06-13T10:48:35","date_gmt":"2023-06-13T14:48:35","guid":{"rendered":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/?page_id=3287"},"modified":"2024-10-09T13:28:31","modified_gmt":"2024-10-09T17:28:31","slug":"zeiss-lsm-980","status":"publish","type":"page","link":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/instrumentation\/zeiss-lsm-980\/","title":{"rendered":"Zeiss LSM 980"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-3335\" src=\"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-content\/uploads\/sites\/1290\/2023\/05\/LSM-980-300x256.jpeg\" alt=\"Zeiss LSM 980 Confocal Microscope\" width=\"500\" height=\"426\" srcset=\"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-content\/uploads\/sites\/1290\/2023\/05\/LSM-980-300x256.jpeg 300w, https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-content\/uploads\/sites\/1290\/2023\/05\/LSM-980-1024x872.jpeg 1024w, https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-content\/uploads\/sites\/1290\/2023\/05\/LSM-980-768x654.jpeg 768w, https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-content\/uploads\/sites\/1290\/2023\/05\/LSM-980-1536x1309.jpeg 1536w, https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-content\/uploads\/sites\/1290\/2023\/05\/LSM-980-2048x1745.jpeg 2048w, https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-content\/uploads\/sites\/1290\/2023\/05\/LSM-980-600x511.jpeg 600w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/p>\n<p><span class=\"TextRun SCXW219558827 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW219558827 BCX0\">Inverted confocal microscope with<\/span><span class=\"NormalTextRun SCXW219558827 BCX0\">\u00a0<\/span><span class=\"NormalTextRun SCXW219558827 BCX0\">multiplexed <\/span><span class=\"NormalTextRun SpellingErrorV2Themed SCXW219558827 BCX0\">Airyscan<\/span> <span class=\"NormalTextRun SCXW219558827 BCX0\">2 detection<\/span> <span class=\"NormalTextRun SCXW219558827 BCX0\">for super-resolution imaging<\/span><span class=\"NormalTextRun SCXW219558827 BCX0\">, a motorized <span class=\"NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW219558827 BCX0\">X,Y<\/span> stage and Z focus with <span class=\"NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW219558827 BCX0\">high speed<\/span> Piezo insert, <\/span><span class=\"NormalTextRun SCXW219558827 BCX0\">and <\/span><span class=\"NormalTextRun SCXW219558827 BCX0\">AI Sample Finder<\/span><span class=\"NormalTextRun SCXW219558827 BCX0\"> for fast sample detection and navigation.<\/span><\/span><span class=\"EOP SCXW219558827 BCX0\" data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<h2><strong>Location:<\/strong> 5114 MEJ<\/h2>\n<h2 style=\"text-align: left\"><strong>Modalities<\/strong><\/h2>\n<ul>\n<li>Z-stack Acquisition<\/li>\n<li>Mosaic Imaging<\/li>\n<li>AI Sample Finder<\/li>\n<li>Definite Focus<\/li>\n<li>Time-lapse Live Cell Multi-position Imaging<\/li>\n<\/ul>\n<h2><strong>Acknowledgements<\/strong><\/h2>\n<p>We suggest using the following language if the Zeiss LSM 980 was used in acquiring your images and data:<\/p>\n<p><em><span class=\"notion-enable-hover\" data-token-index=\"0\">&#8220;The Zeiss LSM 980 microscope was funded with support from NIH grant S10 OD032388.&#8221;<\/span><\/em><\/p>\n<h2><strong>Specifications<\/strong><a id=\"Specifications\"><\/a><\/h2>\n<h4><em>Objectives<\/em><\/h4>\n\n<table id=\"tablepress-34\" class=\"tablepress tablepress-id-34 tablepress-responsive\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\">Magnification<\/th><th class=\"column-2\">NA<\/th><th class=\"column-3\">WD (mm)<\/th><th class=\"column-4\">Correction<\/th><th class=\"column-5\">Immersion<\/th><th class=\"column-6\">Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.micro-shop.zeiss.com\/en\/us\/shop\/objectives\/420330-9901-000\/Objective-EC-Plan-Neofluar-5x-0.16-M27\" rel=\"noopener\" target=\"_blank\">5X<\/a><\/td><td class=\"column-2\">0.16<\/td><td class=\"column-3\">18.5<\/td><td class=\"column-4\">Plan-Neofluar<\/td><td class=\"column-5\">Air<\/td><td class=\"column-6\"><\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.micro-shop.zeiss.com\/en\/us\/shop\/objectives\/420640-9900-000\/Objective-Plan-Apochromat-10x-0.45-M27\" rel=\"noopener\" target=\"_blank\">10X<\/a><\/td><td class=\"column-2\">0.45<\/td><td class=\"column-3\">2<\/td><td class=\"column-4\">Plan-Apochromat<\/td><td class=\"column-5\">Air<\/td><td class=\"column-6\"><\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.micro-shop.zeiss.com\/en\/us\/shop\/objectives\/420650-9903-000\/Objective-Plan-Apochromat-20x-0.8-M27\" rel=\"noopener\" target=\"_blank\">20X<\/a><\/td><td class=\"column-2\">0.8<\/td><td class=\"column-3\">0.55<\/td><td class=\"column-4\">Plan-Apochromat<\/td><td class=\"column-5\">Air<\/td><td class=\"column-6\"><\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.micro-shop.zeiss.com\/en\/us\/shop\/objectives\/420762-9800-799\/Objective-Plan-Apochromat-40x-1.3-Oil-DIC-M27\" rel=\"noopener\" target=\"_blank\">40X<\/a><\/td><td class=\"column-2\">1.3<\/td><td class=\"column-3\">0.2<\/td><td class=\"column-4\">Plan-Apochromat<\/td><td class=\"column-5\">Oil<\/td><td class=\"column-6\"><\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.micro-shop.zeiss.com\/en\/us\/shop\/objectives\/420762-9800-799\/Objective-Plan-Apochromat-40x-1.3-Oil-DIC-M27\" rel=\"noopener\" target=\"_blank\">63X<\/a><\/td><td class=\"column-2\">1.4<\/td><td class=\"column-3\">0.19<\/td><td class=\"column-4\">Plan-Apochromat<\/td><td class=\"column-5\">Oil<\/td><td class=\"column-6\"><\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.micro-shop.zeiss.com\/en\/us\/shop\/objectives\/420852-9871-799\/Objective-LD-LCI-Plan-Apochromat-25x-0.8-Imm-Corr-DIC-M27\" rel=\"noopener\" target=\"_blank\">25X<\/a><\/td><td class=\"column-2\">0.8<\/td><td class=\"column-3\">0.57<\/td><td class=\"column-4\">Plan-Apochromat<\/td><td class=\"column-5\">Multi-immersion<\/td><td class=\"column-6\">Available upon request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n<h4><em>Lasers<\/em><\/h4>\n\n<table id=\"tablepress-31\" class=\"tablepress tablepress-id-31 tablepress-responsive\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\">Excitation (nm)<\/th><th class=\"column-2\">Dyes<\/th><th class=\"column-3\">Type<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\">405<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">Diode<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\">488<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">Diode<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\">561<\/td><td class=\"column-2\"> <\/td><td class=\"column-3\">Diode<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\">633<\/td><td class=\"column-2\"><\/td><td class=\"column-3\">Diode<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n<h4><em>Detectors<\/em><\/h4>\n\n<table id=\"tablepress-32\" class=\"tablepress tablepress-id-32 tablepress-responsive\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\">Type<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\">2 flanking multialkali PMT detectors<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\">4 channel GaAsP detectors<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\">Airyscan2 GaAsP array detector<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\">Transmitted light PMT detector<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n<h4><em>Software<\/em><\/h4>\n\n<table id=\"tablepress-35\" class=\"tablepress tablepress-id-35 tablepress-responsive\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\">Version<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\">ZEN Blue 3.9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n<h2><strong>Filter Spectra<\/strong><a id=\"Filter_Spectra\"><\/a><\/h2>\n\n<table id=\"tablepress-41\" class=\"tablepress tablepress-id-41 tablepress-responsive\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\">Filter Set<\/th><th class=\"column-2\">Excitation<\/th><th class=\"column-3\">Beamsplitter<\/th><th class=\"column-4\">Emission<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.micro-shop.zeiss.com\/en\/us\/shop\/filterAssistant\/filtersets\/489090-9110-000\" rel=\"noopener\" target=\"_blank\">Filter Set 90 HE LED<\/a><\/td><td class=\"column-2\">BP 385\/30<br \/>\nBP 469\/38<br \/>\nBP 555\/30<br \/>\nBP 631\/33<\/td><td class=\"column-3\">QBS 405 + 493 + 575 + 653<\/td><td class=\"column-4\">QBP 425\/30 + 514\/30 + 592\/25 + 709\/100<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.micro-shop.zeiss.com\/en\/us\/shop\/filterAssistant\/filtersets\/489112-9110-000\" rel=\"noopener\" target=\"_blank\">Filter Set 112 HE LED<\/a><\/td><td class=\"column-2\">BP 385\/30<br \/>\nBP 469\/38<br \/>\nBP 555\/30<br \/>\nBP 631\/33<\/td><td class=\"column-3\">PBP 405 + 493 + 575 + 674 + 761<\/td><td class=\"column-4\">PBP 425\/30 + 514\/31 + 592\/25 + 681\/45 + 785\/38<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n","protected":false},"excerpt":{"rendered":"<p>Inverted confocal microscope with\u00a0multiplexed Airyscan 2 detection for super-resolution imaging, a motorized X,Y stage and Z focus with high speed Piezo insert, and AI Sample Finder for fast sample detection and navigation.\u00a0 Location: 5114 MEJ Modalities Z-stack Acquisition Mosaic Imaging AI Sample Finder Definite Focus Time-lapse Live Cell Multi-position Imaging Acknowledgements We suggest using the &hellip; <a href=\"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/instrumentation\/zeiss-lsm-980\/\" aria-label=\"Read more about Zeiss LSM 980\">Read more<\/a><\/p>\n","protected":false},"author":111865,"featured_media":0,"parent":2395,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":"","_links_to":"","_links_to_target":""},"class_list":["post-3287","page","type-page","status-publish","hentry","odd"],"acf":[],"_links_to":[],"_links_to_target":[],"_links":{"self":[{"href":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-json\/wp\/v2\/pages\/3287","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-json\/wp\/v2\/users\/111865"}],"replies":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-json\/wp\/v2\/comments?post=3287"}],"version-history":[{"count":0,"href":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-json\/wp\/v2\/pages\/3287\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-json\/wp\/v2\/pages\/2395"}],"wp:attachment":[{"href":"https:\/\/www.med.unc.edu\/neuroscience\/neuro-microscopy\/wp-json\/wp\/v2\/media?parent=3287"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}