{"id":2266,"date":"2023-06-13T15:15:23","date_gmt":"2023-06-13T19:15:23","guid":{"rendered":"https:\/\/www.med.unc.edu\/rrcf\/?page_id=2266"},"modified":"2023-07-06T14:50:06","modified_gmt":"2023-07-06T18:50:06","slug":"image-guided-irradiator","status":"publish","type":"page","link":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/","title":{"rendered":"Image-Guided X-Ray Irradiator"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2301 alignright\" src=\"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart-244x300.jpg\" alt=\"Smart Irradiator\" width=\"211\" height=\"260\" srcset=\"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart-244x300.jpg 244w, https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart.jpg 330w\" sizes=\"auto, (max-width: 211px) 100vw, 211px\" \/>The Small Animal Radiation Therapy (SmART+) system (Precision X-ray, Inc.) is an image-guided irradiator dedicated for preclinical research involving radiation. The system was acquired in 2022 through the Cs-Irradiator Replacement Project (CIRP) sponsored by the Department of Energy. It can provide CT image-guided radiation to a target tissue\/region, and deliver precise radiation with high repeatability. The CT imaging unit can provide images at a nominal resolution of 100 microns. The system is equipped with (5) fixed collimators as well as an adjustable collimator unit.<\/p>\n<p>The primary features include:<\/p>\n<ul>\n<li><strong>Irradiation Energy<\/strong>: 10-225 kVp, 4500 W<\/li>\n<li><strong>Dose rate<\/strong>: 1-6 Gy\/min<\/li>\n<li><strong>Collimation<\/strong>: conformal collimators available in sizes from 1 mm to 100 mm<\/li>\n<li><strong>Isocenter distance<\/strong>: 30 cm typical<\/li>\n<li><strong>Image-guided targeting precision<\/strong>: up to 0.1 mm<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The Small Animal Radiation Therapy (SmART+) system (Precision X-ray, Inc.) is an image-guided irradiator dedicated for preclinical research involving radiation. The system was acquired in 2022 through the Cs-Irradiator Replacement Project (CIRP) sponsored by the Department of Energy. It can provide CT image-guided radiation to a target tissue\/region, and deliver precise radiation with high repeatability. &hellip; <a href=\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/\" aria-label=\"Read more about Image-Guided X-Ray Irradiator\">Read more<\/a><\/p>\n","protected":false},"author":55643,"featured_media":0,"parent":2260,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":"","_links_to":"","_links_to_target":""},"class_list":["post-2266","page","type-page","status-publish","hentry","odd"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Image-Guided X-Ray Irradiator - Research Radiation Core Facility<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Image-Guided X-Ray Irradiator - Research Radiation Core Facility\" \/>\n<meta property=\"og:description\" content=\"The Small Animal Radiation Therapy (SmART+) system (Precision X-ray, Inc.) is an image-guided irradiator dedicated for preclinical research involving radiation. The system was acquired in 2022 through the Cs-Irradiator Replacement Project (CIRP) sponsored by the Department of Energy. It can provide CT image-guided radiation to a target tissue\/region, and deliver precise radiation with high repeatability. &hellip; Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/\" \/>\n<meta property=\"og:site_name\" content=\"Research Radiation Core Facility\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-06T18:50:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart-244x300.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/\",\"url\":\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/\",\"name\":\"Image-Guided X-Ray Irradiator - Research Radiation Core Facility\",\"isPartOf\":{\"@id\":\"https:\/\/www.med.unc.edu\/rrcf\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart-244x300.jpg\",\"datePublished\":\"2023-06-13T19:15:23+00:00\",\"dateModified\":\"2023-07-06T18:50:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#primaryimage\",\"url\":\"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart.jpg\",\"contentUrl\":\"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart.jpg\",\"width\":330,\"height\":406,\"caption\":\"Precision Smart Irradiator\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.med.unc.edu\/rrcf\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Equipment\",\"item\":\"https:\/\/www.med.unc.edu\/rrcf\/equipment\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Image-Guided X-Ray Irradiator\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.med.unc.edu\/rrcf\/#website\",\"url\":\"https:\/\/www.med.unc.edu\/rrcf\/\",\"name\":\"Research Radiation Core Facility\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.med.unc.edu\/rrcf\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Image-Guided X-Ray Irradiator - Research Radiation Core Facility","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/","og_locale":"en_US","og_type":"article","og_title":"Image-Guided X-Ray Irradiator - Research Radiation Core Facility","og_description":"The Small Animal Radiation Therapy (SmART+) system (Precision X-ray, Inc.) is an image-guided irradiator dedicated for preclinical research involving radiation. The system was acquired in 2022 through the Cs-Irradiator Replacement Project (CIRP) sponsored by the Department of Energy. It can provide CT image-guided radiation to a target tissue\/region, and deliver precise radiation with high repeatability. &hellip; Read more","og_url":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/","og_site_name":"Research Radiation Core Facility","article_modified_time":"2023-07-06T18:50:06+00:00","og_image":[{"url":"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart-244x300.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/","url":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/","name":"Image-Guided X-Ray Irradiator - Research Radiation Core Facility","isPartOf":{"@id":"https:\/\/www.med.unc.edu\/rrcf\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#primaryimage"},"image":{"@id":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#primaryimage"},"thumbnailUrl":"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart-244x300.jpg","datePublished":"2023-06-13T19:15:23+00:00","dateModified":"2023-07-06T18:50:06+00:00","breadcrumb":{"@id":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#primaryimage","url":"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart.jpg","contentUrl":"https:\/\/www.med.unc.edu\/rrcf\/wp-content\/uploads\/sites\/1375\/2023\/06\/Smart.jpg","width":330,"height":406,"caption":"Precision Smart Irradiator"},{"@type":"BreadcrumbList","@id":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/image-guided-irradiator\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.med.unc.edu\/rrcf\/"},{"@type":"ListItem","position":2,"name":"Equipment","item":"https:\/\/www.med.unc.edu\/rrcf\/equipment\/"},{"@type":"ListItem","position":3,"name":"Image-Guided X-Ray Irradiator"}]},{"@type":"WebSite","@id":"https:\/\/www.med.unc.edu\/rrcf\/#website","url":"https:\/\/www.med.unc.edu\/rrcf\/","name":"Research Radiation Core Facility","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.med.unc.edu\/rrcf\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links_to":[],"_links_to_target":[],"_links":{"self":[{"href":"https:\/\/www.med.unc.edu\/rrcf\/wp-json\/wp\/v2\/pages\/2266","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.med.unc.edu\/rrcf\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.med.unc.edu\/rrcf\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/rrcf\/wp-json\/wp\/v2\/users\/55643"}],"replies":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/rrcf\/wp-json\/wp\/v2\/comments?post=2266"}],"version-history":[{"count":0,"href":"https:\/\/www.med.unc.edu\/rrcf\/wp-json\/wp\/v2\/pages\/2266\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/rrcf\/wp-json\/wp\/v2\/pages\/2260"}],"wp:attachment":[{"href":"https:\/\/www.med.unc.edu\/rrcf\/wp-json\/wp\/v2\/media?parent=2266"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}