{"id":2307,"date":"2013-10-24T21:35:00","date_gmt":"2013-10-25T01:35:00","guid":{"rendered":"https:\/\/www.med.unc.edu\/timetoconceive\/study-participant-resources\/ovulation-predictor-test-instructions\/"},"modified":"2018-06-29T10:59:03","modified_gmt":"2018-06-29T14:59:03","slug":"ovulation-predictor-test-instructions","status":"publish","type":"page","link":"https:\/\/www.med.unc.edu\/timetoconceive\/study-participant-resources\/ovulation-predictor-test-instructions\/","title":{"rendered":"Ovulation Predictor Test Instructions"},"content":{"rendered":"<p><!-- description --><\/p>\n\n<p><em>Instructions on how to use your ovulation predictor tests.<\/em><\/p>\n<div>\n<p><b>Please read the entire set of instructions before beginning to test<\/b>. If you have any questions, please don\u2019t hesitate to contact us at 919-843-8246 or at <a href=\"mailto:fertility@unc.edu?subject=Question About Ovulation Predictor Test\"><span style=\"text-decoration: underline;\">fertility@unc.edu<\/span>.<\/a><\/p>\n<h2>Step 1: Determining when to start testing<\/h2>\n<p>Use the Menstrual Cycle Chart below to find out when to begin testing. Count \u201cDay 1\u201d as the first day of real bleeding (not just spotting), and count through to the day before your next period starts. This is \u201cYour Usual Cycle Length\u201d. You can test any time of day, but it should be at about the same time each day. It is important that you have not urinated for at least 4 hours before testing, and you should avoid excessive fluid intake before testing.<\/p>\n<h3 style=\"text-align: center;\">Menstrual Cycle Chart<\/h3>\n<table class=\"table table-hover\" style=\"width: 769px; height: 187px;\" border=\"0\">\n<tbody>\n<tr>\n<th style=\"text-align: center;\">Your Usual Cycle Length<\/th>\n<th style=\"text-align: center;\">Day to Begin Testing<\/th>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">&lt; 26 days<\/td>\n<td style=\"text-align: center;\">Day 6<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">27 \u2013 29 Days<\/td>\n<td style=\"text-align: center;\">Day 8<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">30 \u2013 35 Days<\/td>\n<td style=\"text-align: center;\">Day 10<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">&gt; 35 Days<\/td>\n<td style=\"text-align: center;\">Day 12<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Too irregular to tell<\/td>\n<td style=\"text-align: center;\">Day 8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Step 2: Testing Procedure<\/h2>\n<p>Remove the <strong>Test Stick<\/strong> from the foil wrapper. Before applying urine to the test strip it must be inserted into the <strong>Test Holder<\/strong>. Follow the steps below.<\/p>\n<ol>\n<li>Remove the <strong>Cap<\/strong> and find the <span style=\"color: #ff3399;\"><strong>Pink Arrow <\/strong><\/span>on the <strong>Test Stick<\/strong>. <img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"51\" class=\"image-inline size-medium wp-image-2308\" style=\"display: block; margin-left: auto; margin-right: auto;\" title=\"OPK Test Stick\" src=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/teststick-300x51.png\" alt=\"OPK Test Stick\" srcset=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/teststick-300x51.png 300w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/teststick-150x26.png 150w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/teststick-768x132.png 768w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/teststick-1024x176.png 1024w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/teststick.png 1177w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/li>\n<li>Find the <span style=\"color: #ff3399;\"><strong>Pink Arrow<\/strong><\/span> on the <strong>Test Holder<\/strong>. Line up <strong><span style=\"color: #ff3399;\">both Pink Arrows<\/span><\/strong> as shown in the picture: <img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"53\" class=\"image-inline size-medium wp-image-2309\" style=\"display: block; margin-left: auto; margin-right: auto;\" title=\"Before Click\" src=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/beforeclick-300x53.jpg\" alt=\"Before Click\" srcset=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/beforeclick-300x53.jpg 300w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/beforeclick-150x26.jpg 150w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/beforeclick-768x135.jpg 768w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/beforeclick.jpg 865w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/li>\n<li>Insert the <strong>Test Stick<\/strong> into the <strong>Test Holder<\/strong> until it clicks into place and the <strong>Test Ready<\/strong> symbol appears. When the Test Ready symbol appears perform the test right away.<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"126\" class=\"image-inline size-medium wp-image-2310\" style=\"display: block; margin-left: auto; margin-right: auto;\" title=\"After Click\" src=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/copy_of_afterclick-300x126.jpg\" alt=\"After Click\" srcset=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/copy_of_afterclick-300x126.jpg 300w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/copy_of_afterclick-150x63.jpg 150w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/copy_of_afterclick.jpg 693w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/li>\n<li>\n<div class=\"WordSection1\">\n<p>To perform the test, with the <strong>Test Ready<\/strong> symbol showing on the display, either: (1) Test directly by placing just the <strong>Absorbent Tip<\/strong>, pointing downwards, in your urine stream for 5-7 seconds. Take care not to get the <strong>Test Holder<\/strong> wet. \u2013 <b>OR <\/b>\u2013 (2) Test a sample of your urine collected in a clean, dry container. Dip just the <strong>Absorbent Tip<\/strong> in your collected urine sample for 15 seconds. <img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"113\" class=\"image-inline size-medium wp-image-2311\" style=\"display: block; margin-left: auto; margin-right: auto;\" title=\"Testing Procedure border\" src=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/testingborder-300x113.jpg\" alt=\"Testing Procedure border\" srcset=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/testingborder-300x113.jpg 300w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/testingborder-150x56.jpg 150w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/testingborder-768x288.jpg 768w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/testingborder-1024x384.jpg 1024w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/testingborder.jpg 1181w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<\/div>\n<\/li>\n<li>Keep the <strong>Absorbent Tip<\/strong> pointing down or lie the Test flat. The Test Ready symbol will start flashing after 20-40 seconds to show that the test is working. <em>DO NOT EJECT THE <strong>TEST STICK<\/strong><\/em>. Replace the <strong>Cap<\/strong>, then wipe off any excess urine.If the <strong>Test Ready<\/strong> symbol does not start flashing, the test did not work. An error symbol will appear on the Display within 10 minutes of testing. You should re-test with a new <strong>Test Stick<\/strong>, once the error message has cleared (see error messages below).<\/li>\n<li>Within 3 minutes the Display will show your result:This is a <strong>NEGATIVE<\/strong> result. Record your result as \u201cnegative\u201d in your diary. <img loading=\"lazy\" decoding=\"async\" class=\"image-inline size-full wp-image-2312\" title=\"Negative Result\" src=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/noLHsurge.jpg\" alt=\"Negative Result\" width=\"70\" height=\"65\" srcset=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/noLHsurge.jpg 202w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/noLHsurge-150x141.jpg 150w\" sizes=\"auto, (max-width: 70px) 100vw, 70px\" \/>This is a <strong>POSITIVE <\/strong>result. Record your result as \u201cpositive\u201d in your diary. <img loading=\"lazy\" decoding=\"async\" width=\"189\" height=\"189\" class=\"image-inline size-full wp-image-2313\" title=\"Positive Result\" src=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/LHSurge.jpg\" alt=\"Positive Result\" srcset=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/LHSurge.jpg 189w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/LHSurge-150x150.jpg 150w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/LHSurge-64x64.jpg 64w\" sizes=\"auto, (max-width: 189px) 100vw, 189px\" \/>You may now press the \u201cEject\u201d button to remove the <strong>Test Stick<\/strong>. The result of the test can only be read on the <strong>Test Holder Display<\/strong>. You may see one or two blue lines on the <strong>Test Stick<\/strong>, <em>these should be ignored<\/em>. While the <strong>Test Stick<\/strong> is inserted, your result will remain on the display for 8 minutes. If your <strong>Test Stick<\/strong> is still inserted and the display is now blank, eject the Test Stick and the result will appear for 2 minutes. <em>Do not re-insert a used<b> Test Stick.<\/b><\/em><\/li>\n<li>While performing a test the <strong>Test Holder<\/strong> may have been splashed with some urine. Ensure that you wipe it clean. A further test is not possible while your result or any error symbols are on the Display.<\/li>\n<\/ol>\n<p><b>Step 3: When to Stop Testing<\/b><\/p>\n<p>Continue testing for 15 days or until a positive test is observed.<\/p>\n<h2>ERROR MESSAGES<\/h2>\n<p><strong>Error A<\/strong>: (A flashing error symbol.) You have ejected the <strong>Test Stick<\/strong> too soon. Re-insert the <strong>Test Stick<\/strong> into the <strong>Test Holder<\/strong> immediately.<br \/>\n<img loading=\"lazy\" decoding=\"async\" width=\"252\" height=\"152\" class=\"image-inline size-medium wp-image-2314 size-full\" style=\"float: left;\" title=\"Error A\" src=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/errora.jpg\" alt=\"Error A\" srcset=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/errora.jpg 252w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/errora-150x90.jpg 150w\" sizes=\"auto, (max-width: 252px) 100vw, 252px\" \/><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Error B<\/strong>: One of the following has occurred:<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"image-inline size-full wp-image-2315\" style=\"float: left;\" title=\"Error B\" src=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/errorb.jpg\" alt=\"Error B\" width=\"105\" height=\"79\" srcset=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/errorb.jpg 202w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/errorb-150x113.jpg 150w\" sizes=\"auto, (max-width: 105px) 100vw, 105px\" \/><\/p>\n<p>(1) Urine has been applied to the <strong>Absorbent Tip<\/strong> before the <strong>Test Stick<\/strong> was inserted into the <strong>Test Holder<\/strong>, (2) The<strong> Absorbent Tip<\/strong> was not kept pointing downwards or the Test was not laid flat after urine was applied, or (3) Too much or too little urine was applied.<\/p>\n<p>This symbol will be displayed for 8 minutes. When the display is blank, you should test again using a new <strong>Test Stick<\/strong>.<\/p>\n<p><strong>Error C<\/strong>: An error has occurred with the <strong>Test Holder<\/strong>. If you have unused <strong>Test Sticks<\/strong>, do not use them with this <strong>Test Holder<\/strong>. Please contact <strong><a href=\"mailto:fertility@unc.edu\">fertility@unc.edu<\/a><\/strong> or call <strong>919-843-8246<\/strong> for a new <strong>Test Holder<\/strong>.<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"image-inline size-full wp-image-2316\" style=\"float: left;\" title=\"Error C\" src=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/errorc.jpg\" alt=\"Error C\" width=\"95\" height=\"75\" srcset=\"https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/errorc.jpg 190w, https:\/\/www.med.unc.edu\/timetoconceive\/wp-content\/uploads\/sites\/759\/2018\/06\/errorc-150x120.jpg 150w\" sizes=\"auto, (max-width: 95px) 100vw, 95px\" \/><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Instructions on how to use your ovulation predictor tests. Please read the entire set of instructions before beginning to test. If you have any questions, please don\u2019t hesitate to contact us at 919-843-8246 or at fertility@unc.edu. Step 1: Determining when to start testing Use the Menstrual Cycle Chart below to find out when to begin &hellip; <a href=\"https:\/\/www.med.unc.edu\/timetoconceive\/study-participant-resources\/ovulation-predictor-test-instructions\/\" aria-label=\"Read more about Ovulation Predictor Test Instructions\">Read more<\/a><\/p>\n","protected":false},"author":33814,"featured_media":0,"parent":2285,"menu_order":4,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":"","_links_to":"","_links_to_target":""},"class_list":["post-2307","page","type-page","status-publish","hentry","odd"],"acf":[],"_links_to":[],"_links_to_target":[],"_links":{"self":[{"href":"https:\/\/www.med.unc.edu\/timetoconceive\/wp-json\/wp\/v2\/pages\/2307","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.med.unc.edu\/timetoconceive\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.med.unc.edu\/timetoconceive\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/timetoconceive\/wp-json\/wp\/v2\/users\/33814"}],"replies":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/timetoconceive\/wp-json\/wp\/v2\/comments?post=2307"}],"version-history":[{"count":0,"href":"https:\/\/www.med.unc.edu\/timetoconceive\/wp-json\/wp\/v2\/pages\/2307\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.med.unc.edu\/timetoconceive\/wp-json\/wp\/v2\/pages\/2285"}],"wp:attachment":[{"href":"https:\/\/www.med.unc.edu\/timetoconceive\/wp-json\/wp\/v2\/media?parent=2307"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}